UPS COVER JR 10K - 28,5 min.
COVER Online Double-Conversion uninterruptible power supply, with a capacity of 10kVA/10kW. 3:3/3:1 phase configuration.
Number of batteries: 80 x 9Ah
11-Z-JR 10K-240009
AUTONOMY TIME
| JR 10K | Load | Autonomy time [min] |
| 80 x 9Ah | 100% | 28.5 |
| 75% | 41.8 | |
| 50% | 64.4 | |
| 25% | 169.9 |
CHARACTERISTICS
|
|
TECHNICAL SPECIFICATIONS
| Model | JR 10K |
| Power factor | 10kVA / 10kW |
| Phases In/Out | 3:3 / 3:1 |
| Design | Tower |
| Input | |
| Nominal voltage | 380 / 400 / 415 Vac |
| Voltage range | -53% ÷ +30% @ 50% load -24% ÷ +20% @ 100% load |
| Nominal frequency | 50 / 60Hz |
| Frequency range | -20% ÷ +20% |
| THDi | <3% |
| Input power factor | ≥0,99 |
| Output | |
| Nominal voltage | 380 / 400 / 415 VAC lub 220 / 230 / 240 VAC |
| Power factor | 1,0 |
| Voltage regulation statis/dynamic | ±1% / ±2% |
| Nominal frequency | 50 / 60 ± 0,05 Hz |
| Overload caability | 110% - 60 min., 125% - 10 min., 150% - 60 s |
| Short circuit capability | 340% of nominal curent by 200 ms |
| Efficiency in OnLine mode | >96% |
| Efficiency in ECO mode | >99% |
| Crest factor | 3:1 |
| Switching time | 0ms |
| Batteries | |
| Cold start | yes |
| Type of batteries | VRLA, AGM, gel |
| Batteries range | 16 - 20 pcs x 12V |
| Max quantity of internal batteries | 40 x 9Ah/12V |
| Max charging curent | 12A |
| Charging type | 3 – 8 hours up to 90% capacity (configurable) |
| Charging cycle | According to DIN 41773 with automatic charging shutdown according to current and voltage criteria, with time control. |
| Dimensions and weights | |
| Dimensions (S x G x W) | 250 x 627 x 827mm |
| Weight w/o batteries | 44,0 kg |
| Weight with batteries | 154,0 kg |
| Signaling and communication ports | |
| Operating status indicator | LCD + audible alarm |
| Communication | USB, RS232, IntelligentSlot, REPO, EMBS, parallel port Optional: SNMP, ModBus, DryContact, RS485 |
| Environmental conditions | |
| Noise level | <58 dB @ load 100%, <52 dB @ load 50% |
| Operating temperature for UPS | 0°C ÷ 40°C |
| Recommended operating temperature | 15 °C ÷ 25 °C |
| Storage temperature | -20°C ÷ 40°C |
| Humidity | 0 ÷ 95% (non-condensing) |
| Cerifications | |
| Interference immunity | EN62040-2:2016 |
| Safety | EN62040-1:2017, EN62040-3:2011, CE |
| Optional accesories | |
| - SNMP card | |
| - RS485 (Modbus) card | |
| - AS 400 mini (dry-contact) card | |
| - Environmental sensor (EMD) | |
| - Remote Emergency Power Off button | |
| - External maintenance bypass | |
| - Backfeed protection | |
| - Parallel cables | |
| - Remote LCD panel | |
Due to constant product improvement all specifications are subject to change without notice.