UPS COVER CORE 3TL
COVER Online Double-Conversion, 3kVA/2.4kW uninterruptible power supply. Plug@Play. Tower cabinet (no batteries). Built-in 8A charger. 1:1 phase configuration.
11-CORT-0030E
CHARACTERISTICS
|
|
BACKUP TIME
Load | Backup time [min] | |
CORE 3TL | ||
8 x 26Ah | 100% | 30 |
75% | 40 | |
50% | 82 | |
25% | 181 | |
8 x 45Ah | 100% | 61 |
75% | 84 | |
50% | 136 | |
25% | 392 | |
8 x 65Ah | 100% | 118 |
75% | 165 | |
50% | 266 | |
25% | 629 | |
8 x 110Ah | 100% | 237 |
75% | 390 | |
50% | 623 | |
25% | 1201 |
TECHNICAL SPECIFICATIONS
Model | CORE 3TL |
Power | 3kVA / 2,4kW |
Phases In/Out | 1:1 |
Input | |
Nominal voltage | 208 / 220 / 230 / 240 Vac |
Voltage range | 110÷300 Vac |
Nominal frequency | 50 / 60Hz |
Frequency range | 45 ÷ 65Hz |
THDi | <3% |
Input power factor | ≥0,99 |
Output | |
Nominal voltage | 208 / 220 / 230 / 240 Vac |
Power factor | 0,8 |
Voltge regulation static/dynamic | ±1% / ±3% |
Nominal frequency | 50 / 60 ± 0,05 Hz |
Overloads capability | 110% - 10min., 130% - 60s., >130% - 3s. |
Efficiency in OnLine mode | >92% |
Efficiency in ECO mode | 99% |
Crest factor | 3:1 |
Switching time | 0ms |
Output sockets | 4 x IEC320 C13 |
Batteries | |
Cold start | Yes |
Internal batteries possibility | no batteries |
Nominal voltage | 96Vdc |
Charger curent | 1A/2A/4A/6A |
Charging time | 3 – 8 hours up to 90% capacity (configurable) |
Charging cycle | According to DIN 41773 with automatic charging shutdown according to current and voltage criteria, with time control. |
Dimensions and weights | |
Dimensions (S x G x W) | 145 x 397 x 220 mm |
Weight | 7,4 kg |
Signaling and communication ports | |
Operating status indicator | LCD + audible alarm |
Communication | USB, slot SNMP, złącze EPO |
Environmental conditions | |
Noise level | <46 dB |
Operating temperature for UPS | 0°C ÷ 45°C |
Recommended operating temperature | 15°C ÷ 25°C |
Storage temperature | -25°C ÷ 55°C |
Humidity | 0 ÷ 95% (non-condensing) |
Cerifications | |
Interference immunity | EN 62040-2: 2016, EMC CE |
Safety | EN 62040-1: 2017, EN 62040-3: 2011, LVD, CE |
Environmental compatibility | EN IEC 63000: 2018, EN 62321, RoHS |
Optional accesories | |
- SNMP card | |
- RS485 card (Modbus) | |
- AS 400 mini (dry-contact) card | |
- Environmental sensor (EMD) | |
- Battery racks or battery cabinets | |
- Remote Emergency Power Off button | |
- Remote LCD panel |
Due to constant product improvement all specifications are subject to change without notice.
- Apparent power [kVA]
- 3
- Active power [kW]
- 2,4
- Technology:
- VFI-SS-111 (OnLine DoubleConversion)
- Phase In/Out:
- 1:1
- Output PF:
- 0,8