UPS COVER JR 20K - 45,2 min.
COVER Online Double-Conversion uninterruptible power supply, 20kVA/20kW. 3:3/3:1 phase configuration.
Number of batteries: 32 x 65Ah
11-Z-JR 20K-132065
AUTONOMY TIME
JR 20K | Load | Autonomy time [min] |
32 x 65Ah | 100% | 45.2 |
75% | 59.1 | |
50% | 118.8 | |
25% | 265.8 |
CHARACTERISTICS
|
|
TECHNICAL SPECIFICATIONS
Model | JR 20K |
Power factor | 20kVA / 20kW |
Phases In/Out | 3:3 / 3:1 |
Design | Tower |
Input | |
Nominal voltage | 380 / 400 / 415 Vac |
Voltage range | -53% ÷ +30% @ 50% load -24% ÷ +20% @ 100% load |
Nominal frequency | 50 / 60Hz |
Frequency range | -20% ÷ +20% |
THDi | <3% |
Input power factor | ≥0,99 |
Output | |
Nominal voltage | 380 / 400 / 415 VAC lub 220 / 230 / 240 VAC |
Power factor | 1,0 |
Voltage regulation statis/dynamic | ±1% / ±2% |
Nominal frequency | 50 / 60 ± 0,05 Hz |
Overload caability | 110% - 60 min., 125% - 10 min., 150% - 60 s |
Short circuit capability | 340% of nominal curent by 200 ms |
Efficiency in OnLine mode | >96% |
Efficiency in ECO mode | >99% |
Crest factor | 3:1 |
Switching time | 0ms |
Batteries | |
Cold start | yes |
Type of batteries | VRLA, AGM, gel |
Batteries range | 32 - 40 pcs x 12V |
Max quantity of internal batteries | 40 x 9Ah/12V |
Max charging curent | 12A |
Charging type | 3 – 8 hours up to 90% capacity (configurable) |
Charging cycle | According to DIN 41773 with automatic charging shutdown according to current and voltage criteria, with time control. |
Dimensions and weights | |
Dimensions (S x G x W) | 250 x 627 x 827mm |
Weight w/o batteries | 47,0 kg |
Weight with batteries | 157,0 kg |
Signaling and communication ports | |
Operating status indicator | LCD + audible alarm |
Communication | USB, RS232, IntelligentSlot, REPO, EMBS, parallel port Optional: SNMP, ModBus, DryContact, RS485 |
Environmental conditions | |
Noise level | <58 dB @ load 100%, <52 dB @ load 50% |
Operating temperature for UPS | 0°C ÷ 40°C |
Recommended operating temperature | 15 °C ÷ 25 °C |
Storage temperature | -20°C ÷ 40°C |
Humidity | 0 ÷ 95% (non-condensing) |
Cerifications | |
Interference immunity | EN62040-2:2016 |
Safety | EN62040-1:2017, EN62040-3:2011, CE |
Optional accesories | |
- SNMP card | |
- RS485 (Modbus) card | |
- AS 400 mini (dry-contact) card | |
- Environmental sensor (EMD) | |
- Remote Emergency Power Off button | |
- External maintenance bypass | |
- Backfeed protection | |
- Parallel cables | |
- Remote LCD panel |
Due to constant product improvement all specifications are subject to change without notice.