UPS INSERT 40K - 58,2 min.
COVER Online Double-Conversion uninterruptible power supply, 40kVA/40kW.
Tower UPS.
Battery inside C40 cabinet (40 x 110Ah).
3:3 phase configuration.
11-Z-INSERT 40K-140110
CHARACTERISTICS
|
|
AUTONOMY TIME
| INSERT 40K | Load | Autonomy time [min] |
| INSERT 40K | ||
| C40 (40 x 110Ah) | 100% | 58,2 |
| 75% | 83,2 | |
| 50% | 141,2 | |
| 25% | 353,5 |
TECHNICAL SPECIFICATIONS
| Model | INSERT 40K |
| Power factor | 40kVA / 40kW |
| Phases In/Out | 3:3 |
| Design | Tower |
| Input | |
| Nominal voltage | 380 / 400 / 415 Vac |
| Voltage range |
304 Vac - 485 Vac for 100% load, 138Vac - 304 Vac linear for 40% - 100% load |
| Nominal frequency | 50 / 60Hz |
| Frequency range | 40 - 70Hz |
| THDi | <3% |
| Input power factor | ≥0,99 |
| Output | |
| Nominal voltage | 380 / 400 / 415 VAC |
| Power factor | 1,0 |
| Voltage regulation statis/dynamic | ±1% / ±2% |
| Nominal frequency | 50 / 60 ± 0,05 Hz |
| Overload caability | 105% - constant work, 110% - 60 min., 125% - 10 min., 150% - 60s., >150% - 200ms. |
| Short circuit capability | 300% of nominal curent by 200 ms |
| Efficiency in OnLine mode | >96% |
| Efficiency in ECO mode | >99% |
| Crest factor | 3:1 |
| Switching time | 0ms |
| Batteries | |
| Cold start | yes |
| Type of batteries | VRLA, AGM, gel |
| Batteries range | 32 - 40 pcs x 12V |
| Max quantity of internal batteries | 160 x 9Ah/12V |
| Max charging curent | 15A |
| Charging type | 3 – 8 hours up to 90% capacity (configurable) |
| Charging cycle | According to DIN 41773 with automatic charging shutdown according to current and voltage criteria, with time control. |
| Dimensions and weights | |
| Dimensions of UPS (S x G x W) | 600 x 950 x 1178 mm |
| Weight w/o batteries | 232,0 kg |
| Weight of C40 (40x110Ah) | 1332,0 kg |
| Signaling and communication ports | |
| Operating status indicator | 5'' LCD touchscrean + LED + audible alarm |
| Communication | USB, RS232, RS485, DryContact x6 IntelligentSlot, REPO, parallel port Optional: SNMP, ModBus TCP, Battery temperature sensor (30 and 40kVA) |
| Environmental conditions | |
| Noise level | <58 dB @ load 100%, <55 dB @ load 50% |
| Operating temperature for UPS | 0°C ÷ 40°C |
| Recommended operating temperature | 15 °C ÷ 25 °C |
| Storage temperature | -20°C ÷ 40°C |
| Humidity | 0 ÷ 95% (non-condensing) |
| Cerifications | |
| Interference immunity | EN62040-2:2018 |
| Safety | EN62040-1:2019, EN62040-3:2011, CE |
| Optional accesories | |
| - SNMP card | |
| - Environmental sensor (EMD) | |
| - Remote Emergency Power Off button | |
| - External maintenance bypass | |
| - Backfeed protection | |
| - Parallel cables | |
| - Remote LCD panel | |
Due to constant product improvement all specifications are subject to change without notice.
Related Products ( 16 other products in the same category )